-->
ArchitetturaVeicoliPersonaggiAereoMobiliaElettronicaAnimaliPianteArmiGli SportCiboAnatomia
segnalibro
Segnalibro rimosso

ISS - Sistema di controllo termico Modello 3D

0
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 1
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 2
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 3
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 4
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 5
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 6
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 7
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 1
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 2
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 3
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 4
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 5
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 6
ISS - Sistema di controllo termico royalty-free 3d model - Preview no. 7
Licenza RoyaltySolo editoriale
Ritorni semplici
Miglior prezzo garantito
Funziona fuori dalla scatola
7 visite
edobric

specificazioni

  • Geometriapolygonal
  • poligoni19,966
  • vertici23,798
  • TexturesYes
  • riggedYes
  • AnimatoNo
  • Prontabile in 3DNo
  • Gioco pronto (low poly)No
  • UV mappatoYes
  • UV non avvoltonone

Formati e file

Cinema 4D
(.c4d)
3 MB

advanced
thermal control system.c4d

Descrizione

Professional 3d model of ISS (International Space Station) Thermal Control System. Very high level of detail. This 3d model was made with care and detail in every particular, based on real-world object. Good overall detail with smooth mesh. Models renders clean instantly. Quality model. C4D used for images. The sequential shunt unit (SSU) is designed to coarsely regulate the solar power collected during periods of insolationwhen the arrays collect power during sun-pointing periods. A sequence of 82 separate strings, or power lines, leads from the solar array to the SSU. Shunting, or controlling, the output of each string regulates the amount of power transferred. The regulated voltage setpoint is controlled by a computer located on the IEA and is normally set to around 140 volts. The SSU has an overvoltage protection feature to maintain the output voltage below 200 V DC maximum for all operating conditions. This power is then passed through the BMRRM to the DCSU located in the IEA.
Oct 28, 2019 Data aggiunta
Mar 08, 2022 ultimo aggiornamento

Recensioni

Al momento non ci sono commenti per questo prodotto.
Perché non essere il primo a rompere il ghiaccio?