-->
ArchitekturaPojazdyPostacieSamolotMebleElektronikaZwierzątRoślinyBronieSportJedzenieAnatomia
Zaznaczone
Usunięto zakładkę

ISS - System kontroli termicznej Model 3D

0
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 1
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 2
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 3
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 4
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 5
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 6
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 7
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 1
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 2
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 3
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 4
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 5
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 6
ISS - System kontroli termicznej royalty-free 3d model - Preview no. 7
Licencja bezpłatnaTylko redakcyjne
Proste zwroty
Gwarancja najlepszej ceny
Działa po wyjęciu z pudełka
7 Odwiedziny
edobric

Specyfikacje

  • Geometriapolygonal
  • Wieloboki19,966
  • Wierzchołki23,798
  • TeksturyYes
  • RiggedYes
  • OżywionyNo
  • Gotowy do druku 3DNo
  • Game Ready (low poly)No
  • Mapowanie UVYes
  • Nieopakowane UVnone

Formaty i pliki

Cinema 4D
(.c4d)
3 MB

advanced
thermal control system.c4d
Cinema 4D

tex.zip

Opis

Professional 3d model of ISS (International Space Station) Thermal Control System. Very high level of detail. This 3d model was made with care and detail in every particular, based on real-world object. Good overall detail with smooth mesh. Models renders clean instantly. Quality model. C4D used for images. The sequential shunt unit (SSU) is designed to coarsely regulate the solar power collected during periods of insolationwhen the arrays collect power during sun-pointing periods. A sequence of 82 separate strings, or power lines, leads from the solar array to the SSU. Shunting, or controlling, the output of each string regulates the amount of power transferred. The regulated voltage setpoint is controlled by a computer located on the IEA and is normally set to around 140 volts. The SSU has an overvoltage protection feature to maintain the output voltage below 200 V DC maximum for all operating conditions. This power is then passed through the BMRRM to the DCSU located in the IEA.
Oct 28, 2019 Data dodania
Mar 08, 2022 Ostatnia aktualizacja

Recenzje

Obecnie nie ma recenzji tego produktu.
Dlaczego nie być pierwszym, który złamie lód?